Project Description
The scope of research during testing load included: the static load test of spans, the settlement of bearings and tension measurements. In total nine static load schemes and sixty-eight dynamic load tests were realized.
Performed dynamic test loads: measurement of the spans acceleration and deflections.
Object details:
- Section I:
- Supporting structure: bridge crane system
- Number of span: 4
- Overwall length: 70 m
- Section II:
- Supporting structure: steel arch
- Number of span: 1
- Effective span: 104.5 m
- Section III:
- Supporting structure: bridge crane system
- Numer of span: 6
- Overwall length: 132.5 m